Pitco Frialator L22-345 Fryer User Manual


 
PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
ReplacingthePumpRelay
1. Remove the two (2) screws, which hold the
pump relay, using a Phillips screwdriver.
2. Remove all wires on the pump relay using
needle-nose pliers. See “Simplified Wiring
Diagrams on page 89.
3. Remove the pump relay.
4. Reinstall the new pump relay by following steps
1 through 2 in reverse.
SG/SSHSeriesServiceManual 76