Russell Hobbs RHGC1 Cooktop User Manual


 
To determine the minimum position, ignite the burners and leave them on in
minimum position. Remove the with the help of a small screwdriver fasten or
loosen the bypass screw around 90 angular degrees. When the flame has a
length of at least 4mm, the gas is well distributed. Make sure that the flame does
not die out when passing from the maximum position to the minimum position.
Create an artificial wind with your hand toward the flame to see if the flames are
stable.
For oven burner, operate the oven burner at minimum position for 5 minutes, then
open and close the oven door for 2-3 times to check the flame stability of the
burner.
Reduced flame position adjustment is not required for grill burners.
The position the bypass screw must be loosened for conversion from LPG to NG.
For conversion from NG to LPG, the same screw must be fastened. Make sure
that the appliance is unpluged from the electric mains and the gas supply is open.
Changing the gas inlet:
For some countries, the gas inlet type can be different for NG/LPG gases. In such
a case, remove the current connection components and nuts (if any) and connect
the new gas supply accordingly. In all conditions, all components used in gas
connections should be approved by local and/or international authorities. In all gas
connections, refer to the “Assembly of gas supply and leakage check” clause
explained before.
Figure 15
Figure 14
Bypass Screw
Bypass Screw
Valve with flame failure device
Thermostatic oven valve
For Customer Services, Spare parts & Warranty Information please call 0845 683 8717