Samsung RFG237AABP Refrigerator User Manual


 
20_ Setting Up
Removing any residual matter inside the water supply line
after installing the water fi lter.
1. Turn on the main water supply & turn on the valve to the water supply line.
2. Run water through the dispenser until the water runs clear (approx.
6-7minutes). This will clean the water supply system and remove air from
the lines.
3. Additional clearing time may be required in some households.
4. Open the Refrigerator door and make sure there are no water leaks coming
from the water fi lter.
4. Remove the fi lter cap (
4
) and insert the fi lter into the
lter housing.
5. Slowly turn the water fi lter 90º clockwise to align with
the printing mark on the cover, locking the fi lter in
position. Make sure to align the water fi lter label mark
(
5
) with center of cover fi lter printing as illustrated.
Remember, do not over-tighten.
Reverse Osmosis Water Supply
IMPORTANT : The pressure of the water supply coming out of a reverse osmosis system going to the water
inlet valve of the refrigerator needs to be between 35 and 120 psi (241 and 827 kPa).
If a reverse osmosis water fi ltration system is connected to your cold water supply, the water pressure to the
reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa.)
If the water pressure to the reverse osmosis system is less than 40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment fi lter in the reverse osmosis system is blocked. Replace the fi lter if
necessary.
• Allow the storage tank on the reverse osmosis system to refi ll after heavy usage.
If your refrigerator has a water fi lter, it may further reduce the water pressure when used in conjunction with a
reverse osmosis system. Remove the water fi lter.
If you have questions about your water pressure, call a licensed, qualifi ed plumber.
Be sure to fl ush the dispenser thoroughly or water may leak from it.
This is due to the fact that there is still air in the line.
Setting up your French Door Refrigerator
Turn until the label
is aligned.
Separation
of fi lter cap(red)
Cover fi lter.
4
5
DA68-01827B-17.indb 20DA68-01827B-17.indb 20 2014. 5. 8.  4:392014. 5. 8.  4:39