BG 2000 Specifications and Operating Characteristics
115-volt 50/60 hz 230-volt 50/60 hz
Horsepower 1 HP 1HP
Refrigerant 404-a 404-a
Oil Polyol ester oil Polyol ester oil
Locked rotor amps 76.7 45
Current draw with pump 26.8 amps 14.10 amps
Electrical breaker 30 amp 15 amp double
pole
Maximum refrigerant charge 24 oz 24 oz
Manual reset high pressure cut-out 325 PSIG 325 PSIG
March pump LC-3 LC-3
Integral low voltage thermostat circuit 24-volt AC 24-volt AC
Pressure trends: Gauge pressure PSIG
Water temp 60
degrees F.
Water temp 80
degrees F.
Hi Pressure 175 190
Low Pressure (Warm Plates) 30 30
Low pressure (Cold Plates) 7 to 5 7 to 5
Pressures are approximate: High pressure will momentarily rise beyond operating
pressure until the expansion valve starts to restrict flow. Condensing pressure will be
15 degrees above water temp.
Low pressure will drop from equalized at start up to settle at the indicated low reading in
a period of about 45 minutes depending on the number of plates and starting
temperature. Proper thermostat set up should cycle the compressor in this low-
pressure range.
THE EXPANSION VALVES HAVE BEEN FACTORY ADJUSTED FOR OPTIMUM
PERFORMANCE. DO NOT ADJUST THIS VALVE FOR ANY REASON.
INCORRECT SETTINGS MAY RUIN THE COMPRESSOR!