Sharp MMD24S Microwave Oven User Manual


 
5
MMD24S
MMD24B
PRODUCT DESCRIPTION
SCHEMATICS
TEST PROCEDURE
TOUCH CONTROL PANEL
MICROWAVE DRAWER
DISSASSEMBLY AND
ADJUSTMENT PROCEDURE
WIRING DIAGRAM
PARTS LIST
SERVICE MANUAL
MICROWAVE DRAWER
MMD24S / MMD24B
FOREWORD
This Manual has been prepared to provide Dacor Service Personnel
with Operation and Service Information for the DACOR MICROWAVE
DRAWER.
It is recommended that service personnel carefully study the entire
text of this manual so that they will be qualified to render satisfactory
customer service.
Check the interlock switches and the door seal carefully. Special
attention should be given to avoid electrical shock and microwave
radiation hazard.
WARNING
Never operate the oven until the following points are ensured.
(A) The door is tightly closed.
(B) The door brackets and hinges are not defective.
(C) The door packing is not damaged.
(D) The door is not deformed or warped.
(E) There is no other visible damage with the oven.
Servicing and repair work must be carried out only by trained service
personnel.
DANGER
Certain initial parts are intentionally not grounded and present
a risk of electrical shock only during servicing. Service
personnel - Do not contact the following parts while the ap-
pliance is energized;
Inverter unit that includes High Voltage Capacitor, High Volt-
age Power Transformer, High Voltage Rectifier, Heat sink, etc.,
and Magnetron, High Voltage Harness etc.;
If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
All the parts marked “*” on parts list are used at voltages more
than 250V.
Removal of the outer wrapper gives access to voltage above
250V.
All the parts marked “” on parts list may cause undue microwave
exposure, by themselves, or when they are damaged, loosened
or removed.
1440 Bridge Gate Dr.
Diamond Bar, CA 91765