6
STEP 5: INSTALLATION OF REAR SPACER and EXHAUST DUCT UPPER
1Attach RECTIFIER PLATE L to inside of EXHAUST DUCT UPPER with 4 SCREWS (A) as shown in Figure
5-A.
2Place EXHAUST DUCT UPPER over the oven and EXHAUST DUCT BACK, and attach REAR SPACER
with 2 SCREWS (A) in Figure 5-B.
3
Tighten together EXHAUST DUCT UPPER and EXHAUST DUCT BACK at the left and right sides with 2
SCREWS (A) as shown in Figure 5-B.
STEP 6: INSTALLATION OF EXHAUST DUCT LEFT
1 Attach EXHAUST DUCT LEFT to the left wall of the oven.
2 Tighen with 6 screws (A) as shown in Figure 6.
EXHAUST DUCT UPPER
EXHAUST DUCT BACK
Figure 5-A
Figure 6
SCREW (A)
SCREW (A)
REAR SPACER
SCREW (A)
RECTIFIER PLATE L
EXHAUST DUCT UPPER
SCREW (A)
Figure 5-B
SCREW (A)
SCREW (A)
EXHAUST DUCT
LEFT
EXHAUST DUCT UPPER
DIVIDE PLATE L
RK12S30 2nd 09.1.8, 4:21 PM6