11
Instructions for the Installer
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
(drawing ref. X238)
Nozzle
diameter
1/100 mm
By-pass
Mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.05 50 30 400 76 75
Semi rapid 1.8 65 33 500 131 129
Rapid 3.0 85 45 800 218 215
Fish Burner 1.9 68 45 800 138 136
Ultra rapid 4.0 100 65 1600 291 286
UR2 Inner ring 1.0 46 30 400 73 71
UR2 Outer ring 3.6 68+68 65 1600 284 250
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Drawing
Ref.
Reduced flowrate
(W)
Auxiliary 1.05 72 (X) 400
Semi rapid 1.8 97 (Z) 500
Rapid 3.0 115 (Y) 800
Fish Burner 1.9 94 (X) 800
Ultra rapid 4.0 135 (K) 1600
UR2 Inner ring 1.0 70 (X) 400
UR2 Outer ring 3.6 102 +102 (Z) 1600
3.3 Hob burner layout
BURNERS
1
Auxiliary
2
Semi rapid
3
Rapid
4
WOK
5
Fishpan