INSTALLATION MODEL 400 RESTAURANT RANGES
PAGE 14 OF 64 OPERATORS MANUAL 1182299 REV 3 (05/05) DRAFT
INSTALLATION
8. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through
the 1/4" drilled hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
9. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
10. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending
or kinking of the appliance connector.
For units not equipped with flame safety devices, be sure all valves are turned off prior to disconnecting.
After reconnecting, be sure all valves are turned off and all pilots are lit.
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the
connector and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.