Southbend STRE-3D Electric Steamer User Manual


 
SERVICE STRATOSTEAM COUNTERTOP STEAMER
PAGE 30 OF 48 OWNERS MANUAL 1185184
Figure 19
High-Limit Thermostats Check
Continuity
1. Allow cavity bottom to cool before performing this test.
2. DISCONNECT POWER AT CIRCUIT BREAKER.
3. Remove left side panel.
4. Disconnect wire B4 from left (as shown above) high-limit thermostat.
5. Disconnect wire B5 from right high-limit thermostat.
6. Disconnect remaining high-limit thermostat wires B11 and B12.
7. Test each high-limit thermostat for continuity (as shown above). There should be continuity when the
thermostat is cool. Replace as necessary.
8. Reconnect wires.