Southbend STRE-3D Electric Steamer User Manual


 
STRATOSTEAM COUNTERTOP STEAMER SERVICE
OWNERS MANUAL 1185184 PAGE 31 OF 48
Figure 20
Water-Level-Control Sensor Check
Continuity
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove the left and right side panels.
3. Remove bottom panel (four screws).
4. Remove insulation cover panel (four nuts).
5. Locate the water-level-control sensor (at the rear edge of the rear element block). Disconnect wires B1 and B2
from the sensor.
6. Place test leads across water-level-control sensor terminals (as shown above) and check for continuity when
the sensor is cool. If no continuity, replace sensor.
7. Reconnect wires and reassemble.