Southbend STRE-3EZ Electric Steamer User Manual


 
STRATOSTEAM COUNTERTOP STEAMER SERVICE
OWNERS MANUAL 1185184 PAGE 29 OF 44
Figure 17
High-Limit Thermostats Check
1. Allow cavity bottom to cool before performing this test.
2. DISCONNECT POWER AT CIRCUIT BREAKER.
3. Remove left side panel.
4. Disconnect wire B4 from left side of high-limit thermostat.
5. Disconnect wire B5 from right side of high-limit thermostat.
6. Disconnect remaining high-limit thermostat wires B11 and B12.
7. Test each high-limit thermostat for continuity (as shown above). There should be continuity when the
thermostat is cool. Replace as necessary.
8. Reconnect wires.