Southbend STRE-3EZ Electric Steamer User Manual


 
OPERATION STRATOSTEAM COUNTERTOP STEAMER
PAGE 8 OF 44 OWNERS MANUAL 1185184
SHUTDOWN
Turn lever to the “OFF” position. The water in the bottom of the cavity will automatically drain.
TROUBLESHOOTING BY OPERATOR
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem Possible Causes and Solutions
Steamer does not heat up at all. – Electric power is shut off. Turn on power.
– Not enough water is in steamer. Add water.
– Lime build-up. De-lime steamer cavity (see page 11).
– If water is OK and there is little lime build-up, call repair service.
Steamer does heat up, but does not produce enough steam. – Door is open or ajar. Close steamer door completely.
– Lime build-up. De-lime steamer cavity (see page 11).
– Not enough water. Add water.
Steamer does not drain correctly. – Clogged drain on inside of steamer cavity. Check and clear.
– Clogged drain outside of steamer. Check and clear.