Taylor C706 Freezer User Manual


 
12
Model C706Important: To the Operator
Symbol Definitions
To better communicate in the International arena,
symbols have replaced words on many of our operator
switches, function, and fault indicators. Your Taylor
equipment is designed wit h these International
symbols.
The following chart identifies the symbol definitions.
=OFF
=ON
=MIXLOW
= MIX OUT
=MIXREF
= STANDBY
= WASH
=AUTO
=PUMP
Power Switch
When placed in the ON position, the power switch
allows SOFTECH control panel operation.
Indicator Lights
When the MIX LOW light begins to flash, it indicates
that the mix tank has a low supply of mix and should
be refilled as soon as possible. When the MIX OUT
light begins to flash, it indicates that the mix tank has
been almost completely exhausted and has an
insufficient supply of mix to operate the freezer . At this
time, the STANDBY and AUTO modes are locked out
and the freezer shuts down. To initiate the refrigeration
system, add mix to the tank and press the AUTO key.
The freezer will automatically begin operation.
MIX REF Key
When the MIX REF key is pressed, the light comes on
indicating the mix hopper refrigeration system is
operating. The MIX REF function cannot be cancelled
unless the AUTO or STANDBY modes are cancelled
first.
STANDBY Key
The Separate Hopper Refrigeration System (SHR)
and the Cylinder Temperature Retention System
(CTR) are standard features. The SHR incorporates
the u se of a separate small refrigeration system to
maintain the mix in the hopper below 40_ (4.4_C) to
assure bacteria control. The CTR works with the SHR
to maintain a good quality pr oduct. During long “No
Sale” periods, it is necessary to warm the product in
the freezing cylinder to approximately 35_Fto40_F
(1.7_Cto4.4_C) to prevent overbeating and product
breakdown.
To activate the SHR and CTR, press the STANDBY
key. Remove the air orifice and place the feed tube
(end without the hole) into the mix inlet hole.
When the STANDBY key is pressed, the light comes
on, indicating the CTR (Cylinder Temperature
Retention System) has been activated. In the
STANDBY mode, the WASH and AUTO functions are
automatically c ancelled. The MIX REF function is
automatically locked in to maintain the mix in the
hopper.
To resume normal operation, press the AUTO key.
When the unit cycles off, the product in the freezing
cylinder will be at serving viscosity. At this time, place
the feed tube (end with the hole) into the mix inlet
hole and install the air orifice.