Taylor shake/slush freezer Blender User Manual


 
23
Model 432
Troubleshooting Guide
Section 8 Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
1. No product being
dispensed.
a. Control switch is in the
“OFF” position.
a. Place control switch in the
“AUTO” position.
18
b. Improper mixing of
product.
b. Carefully follow directions
for mixing product.
---
c. Inadequate mix in hopper. c. Fill hopper with mix.
18
d. Product frozen-up in
freezing cylinder.
d. Adjust viscosity
adjustment accordingly.
11
e. Unit out on reset. e. Place control switch in the
“OFF” position. Press the
push-button switch.
Return control switch to
“AUTO”.
11
f. Beater assembly is
rotating counterclockwise.
Control switch is not in
“AUTO”.
f. If the beater is rotating
counterclockwise, call a
service technician to
correct the rotation.
1
g. Unit unplugged at wall
receptacle.
g. Plug in power cord.
---
h. Tripped circuit breaker or
blown fuse.
h. Reset circuit breaker or
replace fuse.
---
2. Unit will not operate in the
“AUTO” or “WASH” mode.
a. Unit unplugged at wall
receptacle.
a. Plug in power cord.
---
b. Tripped circuit breaker or
blown fuse.
b. Reset circuit breaker or
replace fuse.
---
c. Unit out on reset. c. Place the control switch in
the “OFF” position. Press
the push-button switch.
Return control switch to
“AUTO”.
11
3. No compressor operation
in the “AUTO” mode.
a. Beater motor is out on
overload.
a. Place control switch in
“OFF” position. Press the
push-button switch.
Return control switch to
“AUTO”.
11
b. Condenser dirty A/C. b. Clean condenser monthly.
21