Thermador PCG48 Wok User Manual


 
English 11
Natural Gas Requirements:
Inlet Connection: 1/2” NPT (min. 3/4” dia. flex line)
Supply Pressure: 6” min. to 14” max. water column
(14.9 to 34.9 mb)
Manifold Pressure: 5” water column (12.5 mb)
Propane Gas Requirements:
Inlet Connection: 1/2” NPT (min. 3/4” dia. flex line)
Supply Pressure: 11” min. to 14” max. water column
(27.4 mb to 34.9 mb)
Manifold Pressure: 10” water column (24.9 mb)
Hook Up
A manual gas shut-off valve must be installed external
to the appliance, in a location accessible from the front,
for the purpose of shutting off the gas supply. The
supply line must not interfere with the back of the unit.
Make sure the gas supply is turned off at the manual
shut-off valve before connecting the appliance.
The installer should inform the owner of the location of
the gas shut-off valve. Make sure all users know where
and how to shut off the gas supply to the rangetop.
The gas supply connections shall be made by a
competent technician and in accordance with local
codes or ordinances. In the absence of local codes, the
installation must conform to the National Fuel Gas
Code ANSI Z223.1/NFPA54-current issue.
Always use pipe-sealing compound or Teflon
®
tape on
the pipe threads, and be careful not to apply excessive
pressure when tightening the fittings.
All installer-supplied parts must conform to applicable
codes.
Leak testing of the appliance shall be in accordance
with the following instructions.
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Bubbles forming indicate a gas leak. Repair all
leaks immediately after finding them.
WARNING:
Do not use a flame of any kind to check for gas leaks.
CAUTION:
When connecting unit to propane gas, make certain the
propane gas tank is equipped with its own high pressure
regulator in addition to the pressure regulator supplied
with the appliance. The pressure of the gas supplied to
the appliance regulator must not exceed a 14” water
column (34.9 mb).
CAUTION:
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2
psig (3.5kPa).
The appliance and its individual shut off valve must be
disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in
excess of 1/2 psig (3.5kPa.).
When checking the manifold gas pressure, the inlet
pressure to the regulator should be at least 6.0" W.C. for
natural gas or 11.0" for propane.
Do not attempt any adjustment of the pressure regulator.