Thermador PCG48 Wok User Manual


 
English 2
Important Installation Information
Electrical Power Supply
30'' Model:
4 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit
36" Models:
6 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit
4 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15
Amp circuit
48" Model:
6 Burners with Electric Griddle - 120 VAC, 60 Hz., 1 Ph., 15
Amp circuit
Gas Supply
Natural Gas
6” water column (14.9 mb) min., 14” (34.9 mb) maximum
Propane Gas
11” water column (27.4 mb) min., 14” (34.9 mb) maximum
All sealed burners are rated at 18,000 BTU/HR (*15,000
BTU/HR on LP). *All models are convertible to LP/Propane
gas using an accessory conversion kit.
IMPORTANT:
When installing against a combustible surface, a Low Back
guard is required. A THERMADOR
®
Low Back guard must
be purchased separately. See “Step 6: Backguard
Installation” on page 13 for backguard and installation
information.
When using the Flush Island Trim, THERMADOR
recommends a minimum 12” (305 mm) rear clearance to a
combustible surface (see Figure 1, Clearance
Requirements). Clearances from non-combustible
materials are not part of the ANSI Z21.1 scope and are not
certified by CSA. Clearances of less than 12” (305 mm)
must be approved by the local codes and/or by the local
authority having jurisdiction.
It is
strongly recommended that this appliance be installed
in conjunction with a suitable overhead vent hood (see
“Step 1: Ventilation Requirements” on page 3). Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.
Check local building codes for the proper method of
appliance installation. Local codes vary. Installation,
electrical connections and grounding must comply with all
applicable codes. In the absence of local codes the
appliance should be installed in accordance with the
National Electric Code ANSI Z223.1 current issue and
National Gas Code ANSI/NFPA 70 – current issue. In
Canada, installation must be in accordance with the CAN
1-B149.1 and .2 – Installation Codes for Gas Burning
Appliances and/or local codes.
This appliance is equipped with an intermittent/interrupted
ignition device that cycles the two far left surface burners
on and off when in the ExtraLow
®
setting.
CAUTION:
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the rangetop. The maximum gas pressure
to this appliance must not exceed 14.0” water column
(34.9 mb) from the propane gas tank to the pressure
regulator.
CAUTION:
This unit is designed as a cooking appliance. Based on
safety considerations, never use it for warming or
heating a room.
CAUTION:
To eliminate risk of burns or fire caused by reaching over
heated surface units, cabinet storage located above the
surface units should be avoided.