Thermador PRDS48 Double Oven User Manual


 
STEP 2: CABINET PREPARATION
ELECTRICAL SUPPLY, DUAL FUEL RANGES
Installation of Dual Fuel ranges
must be planned so that the
rough-in of the junction box for
the receptacle or conduit connec-
tion will allow maximum clear-
ance to the rear of the unit.
When the power supply cord (not
supplied) or conduit is connected
to the mating receptacle or
junction box cover, the combined
plug/receptacle or junction box
cover/conduit connector should
protrude no more than 2-1/4
inches from the rear wall. See
Figure 3d.
This is especially critical if the
junction box in the wall will be
directly behind the junction box
on the unit when the unit is
installed. Refer to Figures 16
and 16a for location of junction
box on unit. Orient the recep-
tacle or conduit connector to
minimize binding when the unit
is connected to the receptacle or
junction box and slid back in
position.
FIG. 3d Wall Connection
Power Cord & Receptacle
Junction Box & Conduit
Page 7