Thermador PRG304 Double Oven User Manual


 
STEP 4: INSTALLING ANTI-TIP DEVICE
Parts Required for Installation of Anti-Tip Device:
PRG304 and PRG36 All Gas Ranges (Figures 9 and 10)
15-10-948 (2 Each)
15-10-910 (1 Each)
15-10-911 (2 Each)
15-10-771 (1 Each)
15-10-916 (4 Each)
15-10-772 (1 Each)
15-10-909 (1 Each)
Mounting Bracket
FIG. 9 Mounting Kit for PRG304 and PRG36
All-Gas Ranges
PRDS304 and PRDS36 Dual
Fuel Ranges (Figure 11)
Thermador Part No. Qty Description
15-10-916 4 Screw, Phillips,#10 x 1-1/2"
15-10-770 1 Anti-Tip Channel, Adjustable,
IMPORTANT INSTALLATION INFORMA-
TION:
The anti-tip bracket may be attached to a
solid wood cabinet having a minimum wall
thickness of 3/4".
The thickness of the wall or floor may
require use of longer screws, available at
your local hardware store.
In all cases, at least two (2) of the bracket
mounting screws must be fastened to solid
wood or metal.
Use appropriate anchors when fastening the
mounting bracket to any material other
Thermador Part No. Qty Description
15-10-916 4 Screw, Phillips,#10 x 1-1/2"
15-10-771 1 Anti-Tip Channel, Adjust
able, PRG
15-10-772 1 Mounting Bracket, PRG
15-10-909 1 Bolt, Hex Head, 1/4"-20 x
1/2"
15-10-910 1 Nut, Hex, 1/4-20
15-10-911 2 Washer, Flat, 1/4-20
15-10-948 2 Screw, Phillips, #10 x 1/2"
1-17/32"
1-9/32"
5-1/2"
This Hole
For Flush
Mount of
PRG36
This Hole
For Flush
Mount of
PRG304
FIG. 10 Adjustable Anti-Tip Channel PRG304
and PRG36 All-Gas Ranges
FIG. 11 Mounting Kit for PRDS304 and PRDS36
Dual Fuel Ranges
15-10-770 (1 Each)
15-10-916 (4 Each)
than hardwood or metal.
Prepare holes at fastener locations as
identified below:
- For walls, wall studs, or floors composed
of solid wood or metal, drill 1/8" pilot
holes.
- For walls or floors composed of drywall,
sheet-rock or other soft materials, drill 3/
16" holes to a minimum depth of 1-3/4",
then tap plastic anchors into each of the
holes using a hammer.
- For walls or floors composed of concrete or
concrete block, drill 3/16" holes to a
minimum depth of 1-3/4", then tap con
crete anchors into each of the holes using
a hammer.
- For walls or floors having ceramic tile
covering, drill 3/16" holes through the tile
only, then drill into the material behind
the tile as indicated immediately above.
If the range is moved to a new location, the
Anti-Tip Device must be removed and rein-
stalled.
Page 11