Thermador PRG304 Double Oven User Manual


 
GAS AND ELECTRIC SUPPLY ZONES:
STEP 2: CABINET PREPARATION
5/8" Flex Line to
Appliance
NOTE:
A Manual Gas
Shut-Off Valve
(not shown)
must be easily
accessible
through an
adjacent cabinet without
moving
the range.
NOTE:
A Manual Gas
Shut-Off Valve
(not shown)
must be easily
accessible
through an
adjacent cabinet without
moving
the range.
FIG. 3a
Gas & Electrical Supply Zone for PRG304, PRG36 & PRG48 All-Gas Ranges
Typical placement shown.
Other placement of Gas
Supply and Electrical
Receptacle within the
Electrical and Gas Supply
Zone is acceptable.
NOTE:
A Manual Gas
Shut-Off Valve
(not shown) must
be easily accessible
through an adjacent
cabinet without moving
the range.
FIG. 3b Gas & Electrical Supply Zone for PRDS304 Dual-Fuel Ranges
5"
Typical placement shown.
Other placement of Gas Supply
and Electrical Receptacle
within the Electrical and Gas
Supply Zone is acceptable.
Typical placement shown.
Other placement of Gas Supply
and Electrical Receptacle
within the Electrical and Gas
Supply Zone is acceptable.
5/8" Flex Line to
Appliance
3-1/4"
B
4"
A
8" Typ.
Both
Sides
Electrical
Supply Zone
Gas
Supply
Zone
5/8" Flex Line to
Appliance
4-3/4"
5" Typ.
Both
Sides
2" Maximum Protru-
sion from Wall for Gas
Supply
20"
Gas &
Electrical
Supply Zone
1/2"
N.P.T.
Three-Prong,
120 VAC
Receptacle
16"
1/2" N.P.T.
Gas & Electrical
Supply Zone
1 3/4" Maximum
Protrusion from Wall
for Gas Supply
2"
1/2" N.P.T.
3-1/2"
The All-Gas Ranges are factory equipped
with a power supply cord with a three-prong
grounding plug. IT MUST BE PLUGGED
INTO A MATING, GROUNDING-TYPE, 120
VAC RECEPTACLE THAT IS CON-
NECTED TO A CORRECTLY POLARIZED
AND GROUNDED 120 VAC CIRCUIT.
(See STEP 6.)
The range must be connected only to the
type of gas for which it is certified.
If the range is to be connected to propane
gas, ensure that the propane gas supply
tank is equipped with its own high pressure
regulator in addition to the pressure
regulator supplied with the range. (See
STEP 5.)
240 VAC Receptacle
(Shown) or Junction
Box
FIG. 3c Gas & Electrical Supply Zone for PRDS36 and PRDS 48 Dual-Fuel Ranges
240 VAC Receptacle
(Shown) or Junction
Box
The Dual-Fuel ranges may be connected
to the power supply with a 3-pole, 3-
conductor range supply cord kit, a 3-pole,
4-conductor range supply cord kit or by
hard-wiring to the power supply. It is the
responsibility of the installer to provide the
proper wiring components (cord or conduit
and wires) and complete the electrical
connection as dictated by local codes and
ordinances, and/or the National Electric
Code. The units must be properly
grounded. Refer to Step 6 for details.
The range must be connected only to the
type of gas for which it is certified. If the
range is to be connected to propane gas,
ensure that the propane gas supply tank
is equipped with its own high pressure
regulator in addition to the pressure
regulator supplied with the range. (See
STEP 5.)
The Dual-Fuel ranges may be connected
to the power supply with a 3-pole, 3-
conductor range supply cord kit, a 3-pole,
4-conductor range supply cord kit or by
hard-wiring to the power supply. It is the
responsibility of the installer to provide the
proper wiring components (cord or conduit
and wires) and complete the electrical
connection as dictated by local codes and
ordinances, and/or the National Electric
Code. The units must be properly
grounded. Refer to Step 6 for details.
The range must be connected only to the
type of gas for which it is certified. If the
range is to be connected to propane gas,
ensure that the propane gas supply tank is
equipped with its own high pressure
regulator in addition to the pressure regulator
supplied with the range. (See STEP 5.)
Model AB
PRDS36 7" 9"
PRDS48 12" 16"
2" Maximum
Protrusion from Wall
for Gas Supply
Page 6