Thermador SB2B Cooktop User Manual


 
SECTION 5: UNPACKING AND PLACING THE UNIT
LOCATING YOUR
OUTDOOR COOKTOP
Unpack and remove all accessory items, packing materials
and product literature from the unit. Attach the gas
pressure regulator to the end of the manifold as shown
in Figure 3. Note the direction of gas flow. Connect one
end of an approved outdoor gas supply hose to the
regulator inlet. Connect the opposite end of the hose
to the installer supplied shut-off valve. Refer to Section
2 for gas requirements.
The following steps are necessary to
convert for LP operation:
FIGURE 3 NATURAL GAS HOOK-UP
Installer supplied
shut-off Valve must
be easily accessible
Regulator 5.0" W.C.
1/2" NPT
Close Nipple
Adapter 1/2" NPT
to 3/8" flare fitting
Threading compound
must be resistant to
L.P. gas
CONVERSION FROM NATURAL
GAS TO LP (LIQUID PROPANE)
Model SB2B is manufactured at the factory for use with
natural gas, and as such requires conversion for use
with an LP gas supply. The conversion should be done
by a qualified technician or your gas supplier. All orifices
required for conversion are provided with the unit.
1. Remove the grate,
burner caps, ven–
turis and burner
bases.
See Figure 4.
2. Remove the burn-
er orifices. Use a
7mm hex socket
on a 3" ratchet
extension and
apply a piece of
foam tape to the
socket to hold the
orifice in the
socket while re-
moving.
See Figure 5.
3. Replace with the
LP orifices supplied
(number 115).
Tighten until snug.
See Figure 6.
4. Reassemble the
burner bases and
venturis. Reinstall
burner caps and
grate.
Gas Hose
(not supplied)
Steps continue on
next page
8