Thermador SB2B Cooktop User Manual


 
SECTION 3: SITE PREPARATION
BUILT-IN INSTALLATIONS
Determine a suitable location for the cooktop by taking
into account exposure to wind and availability of gas and
electrical supplies. Insure that the gas supply line and
electrical supply are located in close proximity to the
unit.
The 8-foot-long electrical cord attached to the cooktop
exits from the bottom, left rear corner of the rough-in
box. Keep connections to the unit as short as possible
and allow for installation and removal of the unit from
the enclosure.
Allow adequate area around the unit for dissipation of
smoke produced during cooking.
Non-Combustible Enclosure for
SB2B Cooktop
CABINET PREPARATION
The model SB2B is designed for easy installation into
masonry enclosures. For noncombustible applications,
the cooktop drops into the opening shown in Figure 1
(below). A ledge is required to support the cooktop
from the bottom. The supporting ledges must be level
and flat. The counter top should also be level.
It is recommended that ventilation holes are provided in
the enclosure in the event of a gas leak. The installer-
supplied gas shut-off valve must be installed in an easily
accessible location.
36"
3" Min.
36"
12
-5
/8"
11
-3
/4"
22
-3
/4"
Figure 1
2" x 4" x 18"
WOOD SUPPORT
Combustible Construction Clearances
Minimum horizontal clearance from sides and back of
unit to adjacent vertical combustible construction ex-
tending above top of unit, 12" from sides and 12" from
back.
Degagement horizontal minimal a respecter entre les
cotes et l’arriere de l’appareil et une construction
combustible verticale adjacent depassant la partie
superieure de l’appareil, soit 12" (305mm) pounces des
cotes et 12" (305mm) ponces de l’arriere.
Below the cooking surface, combustible construction
can be placed directly adjacent to the unit.
Non-combustible Construction Clearances
Above the cooking surface, a minimum of 12" clearance
from the sides is required to allow adequate access to
pans. A minimum of 3" clearance from the rear is
required to allow for large pan sizes. Below the cooking
surface, non-combustible construction can be placed
directly adjacent to the unit.
In all installations, do not locate this outdoor cooking
gas appliance under unprotected combustible overhead
construction.
II est interdit d’installer le present appareil au-dessous
des surfaces combustibles non protegees.
6