Thermador SB2B Cooktop User Manual


 
NATURAL GAS REQUIREMENTS -
Inlet Connection: 1/2" NPT
Supply Pressure: 6" to 14" W.C.
Manifold Pressure: 5" W.C.
PROPANE GAS REQUIREMENTS -
Inlet Connection: 1/2" NPT
Supply Pressure: 11" to 14" W.C.
Manifold Pressure: 10" W.C.
SECTION 2: GAS REQUIREMENTS
GAS CONSUMPTION
The total gas consumption of the Thermador
®
Outdoor
Cooktop with all burners on "HI" is 30,000 BTU/HR.
CAUTION
The appliance must be isolated from the gas
supply system by closing its individual manual
shut-off valve during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2" psig (3.5kPa).
When checking the manifold gas pressure, the
inlet pressure to the appliance regulator should
be at least 7.0" W.C. for natural gas, and 11.0"
W.C. for propane.
Do not attempt any adjustment of the pressure
regulator.
ATTENTION
L’appareil doit étre isolé du circuit
d’alimentation de gaz en fermant son rob1net
manuel d’isolement individuel pendant toutes
essais sous pression du circuit de tuyauterie
d’alimentation de gaz aux pressions d’essai
égales à ou moins de 3.5kPa (1/2 psig).
En controlant la pression de gaz du tubulure, la
pression de prise au régulateur de l’appareil
devrait étre au moins 11.2mm HG pour gaz
naturel, et 20.5mm HG pour gaz de propane.
N’essayez aucun réglage du régulateur de
pression.
IMPORTANT
Un robinet manuel d'isolement doit étre installé à
l’extérieur de l’appareil, dans un emplacement
accessible avec l’unité installée dans la module.
Assurez-vous que le robinet est fermé avant de
brancher l’appareil.
!
!
IMPORTANT
A manual gas shut off valve must be installed
external to the appliance, in a location accessible
with the unit installed in the enclosure. Make
sure the valve is turned off prior to connecting
the appliance.
CAUTION
When connecting to propane gas supply, make
certain that the propane gas tank is equipped
with its own high pressure regulator in addition
to the pressure regulator supplied with the
appliance. The pressure of the gas at the
appliance regulator must not exceed 14" water
column.
ATTENTION
En se reliant a l approvisionnement de gaz de
propane, assurez-vous que le réservoir de gaz
de propane est équipé de son Propre régulateur
à haute pression en peus du régulateur de
Pression fourni avec l’appareil. La pression du
gaz au régulateur de l’appareil ne doit pas
exéceder 26.1 mm HG.
!
!
!
!
5
For Massachusetts Installations:
1. Shut-off valve must be a “T” handle gas cock.
2. Flexible gas connector must not be longer
than 36 inches.
3. Not approved for installation in a bedroom
or a bathroom unless unit is direct vent.