5
2. Check that the appropriate receptacle is available
for the power cord plug.
3. Insert the power cord plug into its receptacle.
4. If required by national or local codes, connect an
equipotential ground wire to the lug next to the
symbol (shown in Figure 3). The equipotential
ground connection must meet all applicable na-
tional and local code requirements.
Checking the Installation
1. Check that the toaster is properly connected to
the electrical power supply.
2. Switch the circuit breaker/fused disconnect to the
ON (I) position.
3. Switch the switch to the ON (I) position. The
display will flash as the toaster pre-heats.
4. Allow the toaster to pre-heat for 15 minutes, until
appears in the display.
CAUTION - HOT SURFACES
USE CAUTION TO AVOID INJURY.
5. Look inside the toasting chamber and visually
check that the heating elements are heating and
glowing red.
6. Push and hold the key for 2 seconds.
7. Push the key.
8. Check that the digital timer begins counting down.
9. Wait for the preset time to elapse. The control
should sound an alarm as follows:
The control will beep 5 times at 1-second intervals.
Next, the control will beep very rapidly for another
5 seconds.
Next, the control will sound a steady tone.
10. Press the key. The timer will reset, and the
steady tone will shut off.
11. Switch the switch to the OFF (O) position.
The fan will remain in operation to allow the toaster
to cool.
12. After the fan stops, switch the circuit breaker/fused
disconnect to the OFF (O) position.
Electrical Connection
IMPORTANT
An electrical schematic for the toaster is provided
at the back of this Manual.
The electrical connection to the toaster requires a
circuit breaker/fused disconnect. Consult appli-
cable national and local code requirements to de-
termine the rating of the breaker/disconnect. Elec-
trical specifications are listed on the toasters se-
rial plate and in the Specifications section of this
Manual.
The toasters power cord and plug provide an
electrical ground connection. A separate
equipotential ground connection must also be
made if required by national or local codes. The
location of the equipotential ground lug is shown
in Figure 3.
Consult all applicable national and local codes for
further electrical connection requirements.
1. Before proceeding with the electrical connection,
check that the electrical supply matches the
toasters requirements. Refer to the serial plate
and to the Specifications section of this Manual.
WARNING
ENSURE THAT BOTH THE CIRCUIT
BREAKER/FUSED DISCONNECT AND THE
SWITCH ARE IN THE O (OFF) POSITION BE-
FORE PROCEEDING.
WARNING
ENSURE THAT ANY PACKING MATE-
RIAL RESIDUE HAS BEEN REMOVED FROM
INSIDE THE TOASTING CHAMBER.
Figure 3 - Equipotential Ground Connection
Equipotential ground
lug and symbol