Toastmaster MBT240 Toaster User Manual


 
9
TROUBLESHOOTING
PROBLEM
Product is toasted
too dark or too
light.
PROBABLE CAUSE
Toaster was not adequately
preheated.
Preset toasting time is incor-
rect.
Using refrigerated or frozen
bakery products.
CORRECTIVE ACTION
Allow toaster to preheat until (ready) ap-
pears in the display. This should occur about 15
minutes after electrical power is restored to the
toaster.
Enter Programming Mode to increase or decrease
the toasting time as necessary. Refer to the Pro-
gramming section of this Manual.
Bakery products must be at room temperature BE-
FORE toasting for consistent results. Allow a 2-
day-old rotation when using fresh bakery products.
Bakery product is
jammed in toaster.
Loading is excessive.
OR
Product is loaded incorrectly.
OR
Carbonized deposits on
lower deck are sticking to the
bakery product.
Switch the switch to the OFF (O) position. Wait
for the fan to stop operating. Then, switch the circuit
breaker/fused disconnect to the OFF (O) position
and allow the toaster to cool.
Next, carefully clear the jam using a long object as
a probe. The probe should preferably be made of
wood, which is less likely to damage the heating
elements.
WARNING
NEVER USE A PLASTIC OR METAL
OBJECT AS A PROBE TO CLEAR A JAM.
WARNING
DO NOT INSERT THE HANDS INTO THE
TOASTING CHAMBER TO CLEAR A JAM. IF THE
UNIT HAS NOT COMPLETELY COOLED, SEVERE
INJURY MAY RESULT.
After clearing a jam, thoroughly clean the peel and
the lower deck before resuming operation. Refer to
Cleaning the Peel and Lower Deck in this Manual.
Toaster overheats
and shuts down.
Cooling fan is dirty or inop-
erative.
Switch the switch to the OFF (O) position. Wait
for the fan to stop operating. Then, switch the circuit
breaker/fused disconnect to the OFF (O) position
and allow the toaster to cool.
Thoroughly clean the fan before resuming operation.
Refer to Cleaning the Toaster in this Manual.
If the problem persists, or is not described above, contact your Authorized Service Agent.
Switch the switch to the OFF (O) position. Wait
for the fan to stop operating. Then, switch the circuit
breaker/fused disconnect to the OFF (O) position
and allow the toaster to cool.
Restart the toaster, following the procedure in the
Set-up, Operation, and Close Procedures section.
High Limit system has acti-
vated, shutting down the
toaster.