FIN-PRC003-EN© 2001 American Standard Inc. All rights reserved.
Features
and
Benefits
Model EWFB
Electric Wall Fin
Trane electric natural convection heavy
duty wall fin has been designed to be
securely attached to the wall or as an
option floor mounted on pedestals.
Trane wall fin is ideally suited as a
primary heating source, a supplement in
high heat loss areas or as a draft barrier
to help minimize cold wall and window
conditions. Because of its rugged
construction, wall fin is especially
recommended for public areas in
commercial and institutional
applications such as offices, schools,
hospitals, transportation terminals,
churches, dormitories and nursing
homes.
The range of sizes and heat outputs can
be individually combined to form a truly
custom comfort system. The wide
variety of colors, materials and
accessories become architecturally
compatible with any interior concept and
design.
Enclosure Options
•
Enclosures ranging from 2
5
/8" (67 mm),
3
1
/2" (89 mm), 5" (127 mm) and
5
1
/2" (140 mm) depths and 4" (102
mm), 4
1
/2" (114 mm), 6" (152 mm),
7" (178 mm) heights. Model ASHDB is
available in 8" (203 mm) through
20" (508 mm) heights.
•
Front intake models may be installed
directly on finished floors.
•
2’ (.61 M) to 15’ (4.57 M) lengths.
•
1
/4" (6.4 mm) pencil-proof top discharge
extruded aluminum grilles and
extruded aluminum back.
•
One-piece front and top panel snap fits
to back cover for two-piece
construction.
•
Totally-enclosed junction boxes.
•
Full length thermal overload
protection.
•
Bonded aluminum fins for cool surface
temperatures.
•
Standard
1
/2" (13 mm) EMT raceway
between junction boxes.
•
Thermostats single or double-pole.
•
Disconnect switch, double-pole.
•
Transformer relay single-pole and
power relays.
•
Custom lengths to 1' (4.57 M).
•
6" (152 mm) and 12" (305 mm) control
sections for factory mounting of one to
two controls.
•
Extended enclosures extend heater’s
length in 6" (152 mm) increments to a
maximum length of 60" (1524 mm).
•
Blank enclosure sections for all models
to allow branch circuit wiring. Can be
modified for use with hydronic heating
elements.
•
Full line of field adjustable accessories
for virtually perfect wall-to-wall or
mullion-to-mullion fit without field
cutting. Approved as 40 ampere
wireways.
•
UL Listed.
•
1
/4" (6.4 mm) wire mesh, factory
installed on enclosure.
•
No visible mounting screws.
•
Pedestal brackets available for floor
mounting in lobbies or in front of
windows.
DBT — Wall Mount (Bottom Inlet)
3
1
/2" Deep x 6" High — 12-Gauge
Extruded Aluminum Front and Grille
DBF — Floor Mount (Front Inlet) for zero
clearance mounting
CB — Wall Mount (Bottom Inlet)
2
5
/8" Deep x 4
1
/2" High —
14-Gauge Extruded Aluminum Front
and Grille