www.U-LineService.com 16 02/2005
™
CO2075DWR — Ice Maker/Refrigerator
Temperature Controller
The temperature controller (Figure 32) is located in the
top drawer. It consists of an LED display, two LED status
indicator lights and three touchpad buttons. The LED
display shows the refrigerator temperature set point and
is calibrated in degrees Fahrenheit. The controller is
factory programmed for a set point of 38°F for the top
drawer which will show when the unit is first powered up.
The factory set point for the ice compartment is 0°F.
To display actual temperature in the refrigerator, press
the “WARMER” button momentarily. A solid status
indicator light (1, Figure 32) will show the air
temperature reading in the cabinet for approximately 10
seconds.
To adjust the temperature set point, press the “SET TEMP”
button momentarily; the display will flash. Press the
“WARMER” or “COOLER” button as desired to change the
set point. When the desired set point shows on the
display, wait 10 seconds and the new set point will be
saved. Wait 24 hours for the temperature to stabilize
before checking the actual temperature again. The
refrigerator set point range is 34°F to 45°F.
To check the temperature in the ice compartment, press
the “WARMER” button momentarily, and then press and
hold “COOLER” for three seconds.
For more information, see the User Manual. For a quick
reference to indicator light status, see the table below.
Indicator Light Status
Other Settings
Other settings for the unit are factory preset. No adjustments
should be necessary at this time. See the User Manual for
information on:
• Removing the upper drawer’s storage bin
• Removing the lower drawer’s ice bucket
• Adjusting the upper drawer’s organizer, left-to-right or
front-to-back
Start-Up Troubleshooting
Problem
Q
:
Unit does not appear to turn on when switch is set to ON.
Solution
A:
Make sure unit is plugged in and outlet has power (circuit
breaker has not tripped).
Problem
Q
:
Water does not appear to be flowing into unit.
Solution
A:
Check that the water is connected and turned on and the
line is not obstructed. Remember that the ice maker
mechanism will not fill the mold with water until the
mold reaches the proper temperature.
Problem
Q
:
The cubes produced during the first two to three hours of
operation have been discarded. New cubes still appear
cloudy.
Solution
A:
This is normal and is caused by air being trapped in the
cube during fast freezing.
IMPORTANT
See the User Manual’s Troubleshooting Guide for more
solutions.
LED Status Indicates
1 • Solid
• Flashing
• Refrigerator temperature displayed
• Not Applicable
2 • Solid
• Flashing
• Freezer temperature displayed
• Open thermistor — call for service
1 2
Figure 32