32
User’s Manual
Problem Possible Cause Remedy
The unit frosts Unit is manual Models SP18, 95, 98,
up defrost model and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING
Door gasket not Adjust door. See
sealing properly ALIGNING THE DOOR
High ambient Defrost unit manually.
temperatures or See DEFROSTING
humidity
Water is leaking Water supply Tighten fitting. See
out the back connection leaking CONNECTING THE
of the unit WATER SUPPLY
Ice cubes Door gasket not Adjust door. See
sticking together sealing properly ALIGNING THE DOOR
Infrequent use of cubes Break apart cubes
Noise during Copper water supply Carefully bend tubing
operation tubing contacting away from cabinet and
internal components components
Certain sounds are Soft sounds from the fan
normal. and water/dropping
sounds from the ice maker
will be heard.
Fan blade touching Remove obstruction
obstruction (wiring,
foam insulation, etc.)
No ice Bin arm locked in Lower bin arm
upright position
No water to unit. Turn on water or contact
plumber.
Not enough ice Control set too cold Adjust control to a
warmer setting
(COUNTER-CLOCKWISE)
Ice cube size too Set cube size smaller.
large See ADJUSTING ICE
CUBE SIZE
Dirty condenser coils. Clean condenser.
See MAINTENANCE.
Water leaks into Water level set too Set cube size smaller.
ice bucket high See ADJUSTING ICE
CUBE SIZE
Fresh food section Ice bucket not fully Push ice bucket
on Combo units inserted into place
too cold WATER SUPPLY
Flap door not closed Be sure Flap door is
correctly closed correctly.
Unit too cold Temperature control Set control to warmer setting
set too cold (COUNTERCLOCKWISE)
Inaccurate temperature Properly check temperature.
reading.
Users Manual 41923 9/2/03 3:44 PM Page 32