Unified Brands HY-6E(CE) Electric Steamer User Manual


 
OM/SM-HY-6E(CE) 29
OM/SM-HY-6E(CE)
29
8. Remove screws and U-channel from the door. Take
the magnet and block assembly from present
location and place it at the opposite end of the door
channel, with the magnet facing outward from the
door.
9. Remove screws. Remove door handle from cam.
10. Apply NEVER-SEEZ high temperature (rated for
250ºC) anti-seize and lubricating compound to the
cam and Locktite 242 to screw threads.
11. Turn handle and cam 180-degrees from their original
positions and install them on the door with screws.
Be sure handle and cam move smoothly.
12. Be sure door handle is in the DOWN position. Turn
U-channel 180-degrees from its original position, hold
door spring in U-channel open with a screwdriver or
similar tool, and install U-channel.
13. Check operation of the cam. Push up on the door
handle and check if the spring opens. If the spring
does not open, cam and spring are NOT correctly
aligned and problem must be corrected.
14. Apply a light amount of Locktite 242 to screws, then
install screws.
15. Apply Locktite 242 to the hinge-to-steamer bolts, then
install door and hinge mounting bolts. Do NOT
tighten mounting bolts at this time.
16. Align door to steamer. Refer to 10.23, Alignment
procedure.
IMPORTANT. When the door is reversed, the alternate
door switch (installed at time of manufacture) must be
connected to the circuit.
17. From the right side access to the upper portion of the
steamer, disconnect the two leads of the door switch.
18. In between the upper cavity and the lower cavity, the
wires for the alternate door switch may be found.
Connect the two wires from the switch to the wiring
harness.
19. Close steamer door and operate steamer. If steamer
fan does not operate, check location of door magnet
and try operation again. If fan operation problem still
exists, refer to the Troubleshooting Section of this
Manual.
20. Allow steamer to operate for approximately 5
minutes, and then check for leaks. If there are no
leaks then steamer is ready for operation. If there are
leaks around the door, recheck door alignment, and if
necessary, door gasket installation.
10.26 Door Gasket
P/N 094147
1. To install, turn off steamer, and allow to cool.
2. Remove the door hinge using one of the following two
methods:
a) Support door weight and remove hinge pin, or
b) Support weight of the door and remove the two
door-to-hinge bolts.
3. Place the door on a flat, clean, smooth table or similar
support. Be careful not to scratch the door
4. Position door on workbench so that its front is lying
flat, with handle hanging over edge of bench.
5. Remove inner d12oor panel.
6. Remove and discard gasket.
7. Clean back of the inner door panel. Be sure old
sealant is completely removed.
8. Install new door gasket around inner door panel as
shown in the illustration. Be sure the inner door panel
flange is fully inserted into the door gasket groove.
9. Apply a high temperature silicone sealant, such as GE
RTV 180 or equivalent, to the four door spacers.
10. Apply Locktite 242 to the inner door panel mounting
screws.
11. Install inner door panel and door gasket on the door
spacers, and tighten mounting screws.
12. Align door with hinge and insert hinge pin OR apply
Locktite 242 to the door-to-hinge bolts, then install
door and mounting bolts. Do NOT tighten mounting
bolts at this time.
13. Align door to steamer.
10.27 Door Handle, Magnet and Block Assembly
Door Handle P/N 070123
Magnet & Block P/N 069762
Screws P/N 005764
Door Cam P/N 074252
U-Channel Assy P/N 094144
Outer Door Panel P/N 094140
Inner Door Panel P/N 094141
Door Insulation Bd P/N 094192