Vita-Mix VM0141 Blender User Manual


 
13
Motor Base/Control Panel
1.
Unplug the power cord.
2. Gently wash the outside surface with a damp soft cotton cloth moistened with a mild
solution of warm water and nonabrasive detergent or nonabrasive liquid spray cleaner.
NEVER IMMERSE MOTOR BASE IN WATER OR OTHER LIQUID.
3. Thoroughly clean switches so that they work freely. They may become sticky from use.
Unplug the machine and use a wet cloth, moistened with water* and a mild detergent, to
clean around the edges of the switch paddles until they function freely.Work the switches
back and forth a few times to loosen any dried residue under switch. Leaving switches
sticky will damage or burn out the switches. Clean carefully, using caution not to allow
water or other liquids to infiltrate the switch.
4. Dry with a soft cotton cloth.
Lid
Separate the lid and plug. Wash in warm soapy water. Rinse clean under running water and
dry. Reassemble before use. (See page 6.)
Container
1. To Clean: Fill container 1/4 full with warm (110˚F/43˚C) water and add a couple drops of
liquid dishwashing detergent.** Return container to motor base and firmly position the
two-piece lid. Run machine for 30 seconds. Empty container. Repeat this step.
2. To Rinse: Fill container 3/4 full with warm (110˚F/43˚C) water – do not add soap. Return
container to motor base and firmly position the two-piece lid. Run machine for 30
seconds. Empty container.
3. If any solid residue remains, remove the blade assembly (see page 8) and wash all
container parts in warm soapy water. Rinse and drain. Reassemble before next step. Do
not soak the blade assembly.
4. To Sanitize: If all solid residue is gone after step 2 or after completion of step 3,
fill container 3/4 full with a sanitizing solution mix.*** Return container to motor base and
firmly position the two-piece lid.Run machine on a high speed for 30 seconds.Turn machine
off and allow mixture to stand in the container for an additional 1-1/2 minutes. Pour out
sanitizing solution mixture.
5. Return container to motor base and run machine empty for an additional 5 seconds. Do
not rinse after sanitizing. Allow container to air dry.
IMPORTANT NOTES!
* Be sure to wring excess water out of cloth or sponge when cleaning around the controls or any
electrical part.
** To prolongcontainer life, Vita-Mix recommends using soaps with alow Ph balance, such as a liquid
dishwashing detergent (Ivory Liquid
®
).
*** Recommended sanitizing solution: 1.5 tsp. / 7.4 ml institutional or household bleach in
2 qt. / 2.0 Ltr. water.