LIGHTING AND SHUTTING DOWN PILOT BURNERS
NOTE: All adjustment procedures associated with pilot
lighting must be performed by an authorized Vulcan-Hart
installation or service person. The bypass (minimum
burner) flame adjustment must be made at the time
the appliance is installed.
OPEN TOP BURNERS
1. Turn main gas supply ON.
2. Wait 30 seconds, and using a taper, light the open
top pilot.
3. If pilot fails to light, turn main gas supply OFF. Wait
5 minutes and repeat the above procedures.
4. Turn one open top burner valve ON to remove air
from the remaining unit gas lines. Turn the burner
OFF when the gas begins to flow.
Nightly Shutdown
Turn oven burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas supply OFF.
GRIDDLE TOPS/HOT TOPS
1. Turn main gas supply ON.
2. Wait 30 seconds, and using a taper, light the griddle
pilot.
3. If pilot fails to light, turn main gas supply OFF. Wait
5 minutes and repeat Steps 1 through 3.
4. Turn one hot top or griddle top burner valve ON to
remove air from the gas line. Turn burner valve OFF
when gas begins to flow.
Nightly Shutdown
Turn burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas valve OFF.