Vulcan-Hart C24EO3 Electric Steamer User Manual


 
C24EO SERIES STEAMERS - GENERAL
GENERAL
INSTALLATION, OPERATION
AND CLEANING
Refer to the Installation & Operation Manual for
specific instructions.
INTRODUCTION
Features
! Requires no water or drain line connections
(manual fill & manual drain).
! Cast aluminum element block for efficient heat
transfer and distribution.
! Field convertible to single phase or three phase
power depending on the supply available.
! 3.0 gallons maximum holding pan capacity.
Steam Cooking
The C24EO series steamer provides timed or
continuous mode cooking in a pressure-less
compartment. The small physical size of the steamer
offers an efficient way to produce many foods in
small batches. Pressure-less, convection steam
cooking will steam cook fresh foods or will steam
defrost and cook frozen foods providing the
maximum color, flavor and nutritional value with the
least expenditure of energy and labor. The pressure-
less cooking compartment allows the operator to
open and close the door, anytime during a cooking
cycle.
Model Designations
! C24EO3 - 3 pan capacity*
! C24EO5 - 5 pan capacity*
*based on 2.5 inch pan depth
Exterior Dimensions
! C24EO3 - 24" w x 33" d x 19.5" h
! C24EO5 - 24" w x 33" d x 26" h
SPECIFICATIONS
Water Requirements
A potable water supply does not guarantee that it's
suitable for steam generation. The water supply must
be within the following specifications or a local water
treatment specialist may need to be consulted. If a
water treatment system is installed, it must be
properly maintained.
! Hardness* - Less than 3 grains
! Silica - Less than 13 ppm
! Total Chloride - Less than 4 ppm
! Ph range of - 7.0 to 8.0
! Un-dissolved Solids - less then 5 microns
* 17.1ppm = 1 grain of hardness
Electric
MODEL
TOTAL
KW
AMPERAGE PER LINE
3 PHASE 1 PHASE
208V 240V 480V 208V 240V
C24EO3 8 22.2 19.2 - 38.5 33.3
C24EO5 12 33.3 28.9 14.4 57.7 50.0
NOTES:
1. Amperage values in the table are
nominal. Tolerance is +5/-10%.
2. C24EO3 - Shipped for 208V 60-50 HZ 3
phase connection. Field convertible to
240V three phase or 208/240V single
phase. See wiring diagram AI2853.
3. C24EO5 - Shipped for 208V or 240V or
480V 60-50 HZ, 3 phase. 208V and 240V
models are field convertible to 1 phase.
See wiring diagram AI2852.
F25386 (June 2010)Page 3 of 24