Vulcan-Hart EF3 ML-52099 Fryer User Manual


 
3
NOTE: If pilot does not remain lit, repeat steps 2
through 5, but allow a longer period of time before
releasing the combination valve knob. Adjust pilot
flame, if necessary, as outlined under Pilot Adjustment
in Service Procedures and Adjustments.
6. Turn combination valve knob to ON.
SPECIFICATIONS
Gas Data
TOOLS
Standard
Hand tools (standard set)
VOM with AC current tester (any quality VOM
with a sensitivity of at least 20,000 ohms per
volt can be used)
Gas test kit
Temperature tester (thermocouple type)
Manometer
INTRODUCTION
Models
This service manual was written for:
EF3, EF4 and EF5 Gas Fryers.
INSTALLATION
Generally, installations are made by the dealer or
contracted by the dealer or owner. Detailed installation
instructions are included in the Installation and
Operation Manual, which is sent with each fryer.
OIL FILTERING
Filtering instructions are included in the Installation
and Operation Manual.
OPERATION
Detailed operation instructions are included with each
fryer in the Installation and Operation Manual.
CLEANING
Detailed cleaning procedures are included in the
Installation and Operation Manual.
LIGHTING PILOT
1. Turn thermostat OFF.
2. Push combination valve knob in and turn to
OFF.
3. Wait 5 minutes for unburned gas to vent.
4. Push combination valve knob in and turn to
PILOT.
5. While holding the combination valve knob in,
light the pilot with a lit taper. Hold the
combination valve knob in for approximately
30 seconds before releasing.
GENERAL
ledoM sebuT.oN RH/UTB
3FE3 000,09
4FE4 000,021
5FE5 000,051