6. Loosen the packing nut and the holding nut.
7. Remove the high limit bulb from the clamp.
8. Pull the high limit bulb through the underside
of the fry tank and remove the high limit
assembly.
9. Reverse the procedure to install. When
installing the new high limit assembly, do not
kink the high limit capillary. Wrap threads of
packing nut with Teflon tape to prevent
leakage.
THERMOPILE
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
1. Remove heat shield as outlined under Cover
and Panels.
2. Disconnect thermopile lead wires as outlined
under High Limit.
3. Remove burners as outlined under Burners.
4. Remove pilot tubing from pilot.
5. Remove screws holding pilot bracket.