Vulcan-Hart GCO2C ML-114571 Convection Oven User Manual


 
– 4 –
INSTALLATION CODES AND STANDARDS
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI/Z223.1/NFPA #54 (latest edition). Copies may be obtained from The
American Gas Association, Inc., Accredited Standards Committee Z223 @ 400 N. Capital St. NW,
Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park, Quincy, MA
02169-7471.
NOTE: In the Commonwealth of Massachusetts,
All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with
a power means of exhaust shall comply with 248 CMR.
3. Vapor Removal From Cooking Equipment
, NFPA-96 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
4.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National
Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electric Code (latest edition).
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
INSTALLING BASIC OVEN
The basic oven must be installed on 4" (10 cm) or 6" (15 cm) adjustable legs for counter installation or be
mounted on a modular stand. Installations on concrete bases or other supports restricting air circulation
underneath the oven are not advisable and may void the warranty.
Ovens Mounted on Casters
Ovens mounted on casters must use a flexible connector (not supplied
by Vulcan) that complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69 • CSA 6.16 and a quick-disconnect
device that complies with the Standard for Quick-Disconnect Devices
for Use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate
means must be provided to limit movement of the appliance without
depending on the connector and the quick-disconnect device or its
associated piping to limit appliance movement. Attach the restraining
device at the rear of the oven as shown in Fig. 1.
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this
restraint prior to turning the gas supply on and returning the oven to its installation position.
Separate instructions for installing casters to the oven are included with the casters.
Note: If the oven is installed on casters and is moved for any reason, it is recommended that the oven be
releveled front to back and side to side for even baking.
Fig. 1
CONNECT
GAS LINE
STRAIN RELIEF
HERE
PL-53563