LEVELING
Once the oven is in its permanent position, place a carpenter's level on the oven rack. If the oven is installed
on legs, turn the adjustable feet in or out to level oven front-to-back and side-to-side. If the oven is installed
on casters, loosen set screws and turn casters in or out to level oven front-to-back and side-to-side.
Retighten set screws after leveling.
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the applicable portions
of the National Electrical Code and/or other local electrical codes.
Appliances equipped with a flexible electric supply cord are provided with a
three-prong grounding plug. It is imperative that this plug be connected into a properly
grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an
electrician. Do not remove the grounding prong from this plug.
The 120 volt models are equipped with a cord and plug.
Refer to electrical wiring diagram located inside the right side panel; remove control panel for access.
Do not turn the power supply on until after the gas connections have been made and checked for leaks.
ELECTRICAL DATA
Minimum Circuit Ampacity
Model Volts Hertz Phase Maximum Protective Device
AMPS
120 60 1 15
GCO2D 200-240 50 1 15
208-240 60 1 15
GCO2C
120 60 1 15
200-240 50/60 1 15