CONNECT GAS LINE
STRAIN
RELIEF HERE
The range must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
The range must be installed in accordance with:
In the United States of America
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223-1 (latest edition). Copies may be obtained from The American
Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
In Canada
1. Local Codes.
2. CAN/CGA-B149.1 Natural Gas Installation Code (latest edition).
3. CAN/CGA-B149.2 Propane Installation Code (latest edition). Copies may be obtained from The
Canadian Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.
ASSEMBLY
Ranges Mounted on Casters
NOTICE: When the range is mounted on casters, it must be installed with the casters supplied, a
connector (not supplied by Vulcan-Hart) complying with either ANSI-Z21.69 (latest edition) or
CAN/CGA-6.16 (latest edition), and a quick-disconnect device complying with either ANSI-Z21.41
(latest edition) or CAN1-6.9 (latest edition). It must also be installed with restraining means to guard
against transmission of strain to the connector, as specified in the appliance manufacturers
instructions. Attach the restraining device at the rear of the oven (Fig. 1).
Provide a restraining device or other means to limit movement of the range without depending on the
connector and/or any quick-disconnect device or its associated piping to limit movement of the range.
Attach the restraining device to the rear of the range (Fig. 1).
Should it be necessary to disconnect the restraint, turn off the gas supply before disconnection.
Reconnect the restraint before turning the gas supply on and returning the range to its installation
position.
Fig. 1