3. Vapor Removal From Cooking Equipment
, NFPA-96 (latest edition). Copies may be obtained from
The National Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
4.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electric Code (latest edition).
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
INSTALLING BASIC OVEN
The basic oven must be installed on legs or be mounted on a
modular stand. Installations on concrete bases or other supports
restricting air circulation underneath the oven is not advisable
and may void the warranty.
Ovens Mounted on Casters
Ovens mounted on casters must use a flexible connector (not
supplied by Vulcan) that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69 • CSA
6.16 and a quick-disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate means
must be provided to limit movement of the appliance without
depending on the connector and the quick-disconnect device
or its associated piping to limit appliance movement. Attach the
restraining device at the rear of the oven as shown in Fig. 1.
Remove two screws from the rear of the oven and install the tie-down strap shipped with the casters
using these screws (Fig. 1). Attach the gas line strain relief to the tie-down strap at the rear of the oven
(Fig. 1).
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect
this restraint prior to turning the gas supply on and returning the oven to its installation position.
Separate instructions for installing casters to the oven are included with the casters.
Note: If the oven is installed on casters and is moved for any reason, it is recommended that the oven
be releveled front to back and side to side.
Fig. 1
CONNECT
GAS LINE
STRAIN RELIEF
HERE
PL-53563