Vulcan-Hart VC6GD ML-126613 Convection Oven User Manual


 
– 7 –
LEVELING
Make sure that the oven racks are level in the final installed position. If the oven is installed on legs,
turn the adjustable feet in or out to level the oven front-to-back and side-to-side. If the oven is installed
on casters, loosen set screws and turn casters in or out to level the oven front-to-back and side-to-side.
Retighten set screws after leveling.
GAS CONNECTION
SAGATAD
LEDOM
GNITARTUPNIERUSSERPDLOFINAM
larutaN
sesaG.P.L
)enaporP(
larutaN
sesaG.P.L
)enaporP(
DG4CV
DG6CV
rh/UTB000,44rh/UTB000,44
.C.W"5.3
)aPk9.0(
.C.W"01
)aPk5.2(
Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
Location of the gas inlet is at the rear of the oven. Codes require that a gas shutoff valve must be
installed in the gas line ahead of the oven.
Connect gas supply after leveling the oven. The gas supply line must be at least the equivalent of
3
/4 inch (19 mm) iron pipe. Make sure the pipes are clean and free of obstructions, dirt or pipe joint
compound.
The ovens are equipped with fixed burner orifices which coincide with installation elevation.
The oven is provided with a regulator integral to the gas solenoid valve and requires no external
regulator.
CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set
for an outlet pressure of 3.5” W.C. (0.9 kPa) natural gas and 10” W.C. (2.5 kPa) propane gas.
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
A. CHECK ALL JOINTS PRIOR TO THE GAS VALVE (SOLENOID) BEFORE LIGHTING UNIT.
B. CHECK ALL JOINTS BEYOND GAS VALVE (SOLENOID) AFTER UNIT IS LIT.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
When gas supply pressure exceeds
1
/2 psig (3.45 kPa), the oven and its individual shutoff valve must
be disconnected from the gas supply piping system.
When gas supply pressure is
1
/2 psig (3.45 kPa) or less, the oven should be isolated from the gas supply
system by closing its individual manual shutoff valve.
VC4GD
VC6GD
VC4GC
VC6GC