Vulcan-Hart VCG10H ML-126836, VCG10F ML-126837, VCG20H ML-126838 Oven User Manual


 
– 13 –
ON After an initial power-up sequence, the control panel indicator lights and the light
inside the oven are lit. The actual oven temperature is shown in the Temperature
display, – h – – min is in the Time display, and – – is in the Program Number display.
The control will now accept commands. The ON button also cancels a manual
cooking operation of up to 5 Phases. (Pressing the ON button while the oven is
running will open the door. Refer to page 10.)
OFF Shuts off the oven and oven light, opens the oven vent and drains the steam
generator tank (pump takes about a minute).
COOKING MODE
HOT AIR Heat and Fan are ON; steam generator tank fills. Initial temperature setting is 302°F
(range is 35 – 518°F).
STEAM Steam and Fan are ON; steam generator tank fills, if not already full. Initial
temperature setting is 212°F (range is 35 – 212°F) depending on the configuration
setting for your altitude (refer to either page 35 or page 37).
COMBI Heat, Fan and Steam are ON; steam generator tank fills, if not already full. Initial
temperature setting is 302° F (range is 35 – 518°F). The amount of steaming is set
by the number of times you press the Combi key (
1 – 6), indicated by the row of lights.
START STOP Starts or stops a cooking operation. Temperature flashes if door is not locked.
PHASE 15 Indicates the Phase of a cooking program. Allows you to step through and display
the cooking information for each phase of a cooking operation before starting.
COOKING TIME or PROBE TEMPERATURE
TIME Displays the Cooking Time. Time remaining for
ALL phases is normally displayed.
Press the Time key again to display the time remaining for the current phase. When
[ – h – – min ] displays in the time display, the oven is in manual mode (does not
switch oven off at end of cycle).
DOWN Decreases the Cooking Time or Probe Temperature setting.
UP Increases the Cooking Time or Probe Temperature setting.
PROBE Displays the Probe Temperature setting, initially 140°F (range is
70 – 210°F). After
5 seconds, displays the actual Probe Temperature.
OVEN TEMPERATURE or
TEMP Displays the Oven Temp instead of . Normally displays the actual Oven Temp.
Press Temp to display the Oven Temperature setting for 5 seconds and adjust it.
DOWN Decreases the Oven Temperature or setting.
UP Increases the Oven Temperature or
setting.
Displays instead of Oven Temperature (temperature difference is indicated by
__t in the display).
keeps the oven degrees warmer than the actual Probe
Temperature.
must be used with the Probe Temperature.
PROGRAM NUMBER
PROG. Recalls and displays the cooking programs, by number, beginning with 00.
DOWN Decreases the Program Number (range is 00 to 98).
UP Increases the Program Number (range is 00 to 98).
ENTER Stores the cooking parameters (up to 5 Phases) in memory under the Program
Number. Cooking parameters will not be lost during power outage or disconnection.