– 28 –
DELUXE MANUAL CONTROL
SELECTOR SWITCH
•OFF
• CONVECTION H
OT A IR MODE (Temp.Range 35 – 518°F)
• STEAM MODE (
Temp. Range 35 – 212°F)
• COMBI MODE (
Temp. Range 35 – 518°F)
•
COOL DOWN — Door opens to latched position and
fan is on until the set temperature is reached. Fan will
come on if thermostat setting is below the actual
temperature.
• dSCL, Clean Cycle Deliming (page 38)
COOKING TIME or PROBE TEMPERATURE
• SELECT Cooking Time
• DISPLAY Cooking Time Remaining. Press TIME for
three seconds to momentarily display the original
TIME setting.
• SELECT
Probe Temperature, final (Temp. Range 70 – 210°F)
• DISPLAY Probe Temperature setting
OVEN TEMPERATURE
• SELECT Oven Temperature
• DISPLAY Oven Temperature Setting. Press TEMP
for three seconds to momentarily display the actual
Oven Temperature.
DOOR OPEN
START
• START Timer Countdown
• START Probe Cooking Operation
KNOB
• SET Oven Temperature
• SET Probe Temperature
• SET Timer
STEAM FACTOR 1 – 6 Indicator Lights (page 22)
TROUBLE INDICATOR LIGHTS
Air Intake, Heat, Steam, Fan