– 18 –
STANDARD AUTOMATIC COMPARTMENT CONTROLS — VHL2 & VHL3 STEAMERS (Fig. 6)
WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE STEAMER.
WARNING: THE COOKING COMPARTMENTS CONTAIN LIVE STEAM. STAY CLEAR WHILE
OPENING EACH DOOR.
Door Latch
• Holds the door closed.
Door Screw Handle (Not Shown)
• Seals door the gasket against the cabinet.
Cooking Time Control
• Sets the desired cooking time (0 to 60 minutes).
Compartment Switch
• Press the top of the switch to start the timer.
• At the end of the cooking cycle, press the
bottom of the switch to silence the buzzer.
Refer to Steam Cooking with Vulcan Kettles and
Steamers (packed with your steamer) for
suggested cooking times. Also refer to the
Suggested Cooking Guidelines on pages 33 – 35.
Size, weight, pan loading and product quality will
affect cooking times and should be adjusted to
your own requirements.
PREHEATING
Preheat the cooking cavity when the steamer with automatic compartment controls is first used for the
day or whenever the compartment is cold. Keep the door closed during the preheat cycle.
Fig. 6
COOKING
TIME
CONTROL
COMPARTMENT
SWITCH
DOOR
LATCH
COOKING TIME CONTROL
COMPARTMENT SWITCH