Vulcan-Hart WOLF C36IRB Oven User Manual


 
INFRARED BURNER
SYMPTOM POSSIBLE CAUSE
Flame not orange.
1. Orifice incorrect size or dirty.
2. Incorrect gas pressure.
3. Incorrect gas type.
4. Orifice not aligned properely in venturi.
5. Appliance not venting properly.
6. Clogged burner ports.
7. Burner malfunction.
Burner not lighting properly or incorrect burner flame
appearance due to clogged ports.
1. Broiler with Infrared burner is mounted too close to
a fryer or charbroiler and the grease laden air is
causing burner ports to clog. If burner ports are
found to be clogged, install a replacement burner.
NOTE: Grease laden air is detrimental to the life of
the Infrared burner. If a technician sees a broiler with
Infrared burner mounted in a location close to a fryer
or charbroiler, please recommend to the customer
to move the broiler away from the grease laden air
source to prolong the life of the Infrared burner.
SALAMANDER BROILERS RADIANT AND INFRARED - TROUBLESHOOTING
Page 17 of 17 F45530 (0814)