Vulcan-Hart WOLF C36IRB Oven User Manual


 
CONTROL VALVES (36RB/C36RB)
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove
MANIFOLD COVER.
2. Left Valve:
A. Disconnect compression fitting from top of
valve.
B. Remove screws securing manifold to
broiler.
C. Note orientation of elbow on valve then
remove the elbow. Retain for use on
replacement valve.
D. Remove valve from manifold.
Fig. 8
3. Right Valve:
A. Remove
RIGHT SIDE PANEL.
B. Disconnect compression fittings from right
side manifold.
C. Remove screws securing right front
manifold and right side manifold to broiler.
D. Note orientation of control valve then
remove it from the each of the manifolds.
NOTE: When installing, ensure control valve is
perpendicular to the right front manifold.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
4. Reverse procedure to install.
5. Check for proper operation.
Fig. 9
PILOT (36RB/C36RB)
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove
MANIFOLD COVER.
2. Disconnect compression nut from straight pilot
valve fitting.
When disconnecting compression nut
from the straight pilot valve fitting, support the fitting
to prevent damage to pilot flexible tubing.
3. Remove screws securing pilot and bracket to the
broiler.
Fig. 10
4. Remove pilot through broiler cooking area.
SALAMANDER BROILERS RADIANT AND INFRARED - REMOVAL AND REPLACEMENT OF PARTS
F45530 (0814) Page 6 of 17