Fig. 14
5. From inside broiler cooking area, remove cotter
pin securing burner to broiler frame. Retain pin
for reuse.
Fig. 15
6. Lift burner from the rear and slide it off the gas
orifice to remove from broiler.
Fig. 16
7. Reverse procedure to install.
8. Perform
RADIANT BURNER AIR SHUTTER
ADJUSTMENT (36RB/C36RB).
CONTROL VALVES (36IRB/C36IRB)
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove
MANIFOLD COVER.
2. Left Valve:
A. Remove screws securing valve mounting
bracket to broiler
B. Disconnect compression fitting from the
elbows at the top and bottom of valve.
C. Note orientation of elbows on valve then
remove the elbows. Retain for use on
replacement valve.
Fig. 17
3. Right Valve:
A. Remove screws securing valve stem
assembly to valve.
SALAMANDER BROILERS RADIANT AND INFRARED - REMOVAL AND REPLACEMENT OF PARTS