HOOD PLACEMENT
Wolf cooktop wall and island hoods come with
a telescopic chimney flue that allows you to
r
each a ceiling height of 8' (2.4 m) to 9' (2.7 m)
with a finished look. A flue extension to
accommodate 10' (3 m) ceilings is available.
R
efer to page 12 for optional accessories.
I
nstallation of the cooktop wall or island hood
should be 24" (610) to 30" (762) from the
bottom of the hood to the countertop.
IMPORTANT NOTE:
8' (2.4 m) ceilings may
not permit installation of the wall or island
hood at 30" (762) above the countertop.
To determine placement of the wall or island
hood, you must calculate the height of the
telescopic chimney flue. Refer to the chart and
illustration below.
IMPORTANT NOTE:
Both sections of the
telescopic chimney flue must be installed in
order for the chimney to be lifted for service.
5
INSTALLATION INSTRUCTIONS
ACCESSORIES
Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
(B)
FLOOR TO
COUNTERTOP
HEIGHT
(A)
TOTAL
FLOOR TO
CEILING
HEIGHT
(C)
COUNTERTOP
TO BOTTOM
OF HOOD
(F)
MAXIMUM
H
EIGHT OF
HOOD
(D)
BOTTOM
OF HOOD TO
MINIMUM FLUE
EXTENSION
(E) UPPER FLUE TOTAL
H
EIGHT TO CEILING
Model CTWH30 Wall Hood
(A)
(B) (C) (D) (E) (F)
96" (2438) 36" (914) 24" (610) min 30
1
/2" (775) 5
1
/2" (140) 48
1
/2" (1232)
96" (2438) 36" (914) 29
1
/2" (749) max 30
1
/2" (775) 0" 48
1
/2" (1232)
108" (2743) 36" (914) 24" (610) min 30
1
/2" (775) 17
1
/2" (445) 48
1
/2" (1232)
108" (2743)
36" (914)
30" (762) max
3
0
1
/2" (775)
1
1
1
/2" (292)
4
8
1
/2" (1232)
Model CTWH36 Wall Hood
(A) (B) (C) (D) (E) (F)
96" (2438) 36" (914) 24" (610) min 32
11
/16" (830) 3
5
/16" (84) 50
7
/8" (1292)
96" (2438) 36" (914) 27
5
/16" (694) max 32
11
/16" (830) 0" 50
7
/8" (1292)
108" (2743) 36" (914) 24" (610) min 32
11
/16" (830) 15
7
/16" (392) 50
7
/8" (1292)
108" (2743) 36" (914) 30" (762) max 32
11
/16" (830) 9
5
/16" (237) 50
7
/8" (1292)
Model IH4227 Island Hood
(A) (B) (C) (D) (E) (F)
96" (2438) 36" (914) 24" (610) min 33
9
/16" (853) 2
7
/16" (62) 47
1
/16" (1195)
96" (2438) 36" (914) 26
7
/16" (672) max 33
9
/16" (853) 0" 47
1
/16" (1195)
108" (2743) 36" (914) 24" (610) min 33
9
/16" (853) 14
7
/16" (367) 47
1
/16" (1195)
108" (2743)
36" (914)
30" (762) max
33
9
/16" (853)
8
7
/16" (214)
4
7
1
/16" (1195)
Letters cor
respond to those in the illustration.
CALCULATE CHIMNEY FLUE HEIGHT
1
)
F
irst measure
A
(
total kitchen height from
finished floor to finished ceiling height).
2)
Next measure
B
(height from finished floor
to countertop).
3
)
T
hen determine the minimum
C
v
alue
(distance from countertop to bottom of
hood). Refer to the chart below for ceiling
heights from 8' (2.4 m) to 9' (2.7 m).
Dimension
C
must be greater than 24" (610)
and less than 30" (762).
4)
To determine the upper flue section height:
E=A-(C+B+D)
.
IMPORTANT NOTE:
If dimension
E
falls
between 0" (0) and
1
/2" (13), you will need to
modify the flue to affix to the flue attachment
brackets. For ease of installation, Wolf
recommends that dimension
E
be no less
than
1
/2" (13).