Wolf Appliance Company CT15E Cooktop User Manual


 
10
2"*min (51)
CUT-OUTTO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
18"
(457)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
30-INCH OVEN OPENING
33" (838)
RECOMMENDED
CABINET WIDTH
30"min (762)
28
3
/8" (721) COOKTOP
CUT-OUTWIDTH
1
5
/16" (33)
RADIUS
2
7
/16" (62)
19
3
/8" (492)
COOKTOP
CUT-OUT DEPTH
7
/16" (11) RADIUS
30
1
/8"**
(
765
)
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
FRONT OF COUNTERTOP
1
9
/16" (40)
21
1
/8"** (537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
**Minimum dimension, but may be exceeded by up to
1
/8" (3).
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
5
/16"
(
8
)
7
/8"
(22) max
COUNTERTOP
PROFILE
13" max
(330)
24"min
(610)
4"min (102)
SEE COUNTERTOP
CUT-OUT BELOW
SEE COUNTERTOP
CUT-OUT BELOW
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
2"* (51)
E
10"
(254)
4"min (102)
TO OVEN
OPENING
3
1
/2"(89)
4
1
/2" (114)
Overall Dimensions
Countertop Cut-Out
21"
(
533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
5
1
/2" (140)4
1
/4" (108)
CONDUIT
UNFRAMED MODEL CT30EU
The illustrations below provide installation
specifications for Model CT30EU.
For ease of installation, 33" (838) cabinets are
r
ecommended for installation of Model CT30EU.
A Wolf 30" (762) built-in single oven may be
installed below Model CT30EU. For this installa-
tion, unless you are using cabinets deeper
than 24" (610), it is recommended that the
electrical supply be placed in the base cabinet
to the right of the oven. Refer to installation
instructions provided with the built-in oven for
additional specifications.
If Model CT30EU is installed above cabinets,
electrical placement is not critical. A grounded
e
lectrical box should be located within 4'
(1.2 m) of the right rear of the cooktop.
For Model CT30EU installation options, refer
to Unframed Installations on pages 12–13.
IMPORTANT NOTE:
For flush mount applica-
tions, it is recommended to measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.
MODEL CT30EU
Overall Width 30" (762)
Overall Height 4
1
/4" (108)
Overall Depth 21" (533)
Minimum Cabinet Depth 22
3
/4" (578)
Minimum Height Clearance*
4
1
/2" (114)
Cut-Out W
idth 28
3
/8" (721)
Cut-Out Depth 19
3
/8" (492)
INSTALLATION SPECIFICATIONS MODEL CT30EU
WOLF
ELECTRIC COOKTOPS
*Minimum 6
1
/4" (159) clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed conduit dimensions, refer to
the illustration on page 5.
Dimensions may vary to
±
1
/8" (3).