Zanussi ZGS 322 Cooktop User Manual


 
14
BURNER RAPID
AUXILIARY
POSITION MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.75 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.071 0.095 0.031
NOZZLE REFERENCE 11 9 Adjust. 7 0 Adjust.
1/100 mm
NOMINAL THERMAL
POWER kW 2.8 0.75 1.0 0.33
NOMINAL FLOW
RATE g/h 2 02 54 7 2 24
NOZZLE REFERENCE 8 6
42
5 0 2 8
1/100 mm
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Rapid 42
Aeration adjustment none