Zanussi ZKC5030 Electric Pressure Cooker User Manual


 
30
Installation instructions
WARNING!
This appliance must be earthed
If your appliance has been damaged in transit,
contact your supplier immediately. Do not
attempt to install it.
Your appliance left the factory fully packaged to
protect it from damage. If it is delivered without
packaging and damage has occurred, the
manufacturer cannot accept responsibility.
Contact your supplier for advice.
Once the packaging has been removed the
appliance should only be moved by hand. Do not
use a sack barrow or any other aid to lift the
appliance as damage may occur.
To move the appliance, open the oven door and
lift the appliance by holding inside the top of the
compartment.
This is a type X appliance, which means it is
freestanding and can be fitted with cabinets on
one or both sides.
40 min
685 min
Sidewalls, which are above hob level, should be
protected by heat resistant non-combustible
material and must not be nearer than 40mm to
the hob side.
A nominal air gap of 2mm at either side of the
appliance is required to enable the appliance to
be moved into position.
Always ensure an air gap is maintained at
hotplate level. Tiles or other forms of deep wall
covering should not obscure this gap.
Overhanging surfaces or a cooker hood should be
a minimum of 685mm above the hob.
It is important to ensure that the appliance is level
after installation. Levelling feet are fitted to the
appliance to accommodate uneven floors.
Connecting to the electricity
supply
WARNING!
This appliance must be earthed. Do not earth
this appliance to gas supply piping. Connect to
230 - 240V AC supply only.
Connection to the electricity supply must be
carried out by a qualified electrician/competent
person.
The electrical connection should be made using a
double pole isolating switch (cooker socket) with
at least 3mm contact separation in all poles. The
cable must have conductors of sufficiently high
cross-sectional area to prevent overheating and
deterioration.
We recommend you use a new length of 6mm
2
twin core earthed cable to ensure your safety.
The cable should be routed away from potentially
hot areas marked by X.