6) Place lower installation brackets under upper installation
brackets located on left and right sides of hood body,
Fig.7. Note: The wider portion of the lower installation
bracket should be at the bottom.
Fig.7 Fig.8
7) From inside the hood, secure (1) M4x8 screw into
each lower installation bracket. The position of this
screw is adjustable to accomodate various cabinet
bottom thicknesses, Fig.8. Do not fully tighten screw yet.
8) Install (2) 3/16x1” screws into the captive nuts of each
upper installation bracket. Tighten screws to adjust the
height of range hood until there is no gap between the
cabinet bottom and front edge of hood, Fig.9. After hood
is positioned, fully tighten the lower installation bracket
screw from step 7, Fig.8-1.
Fig.9 Fig.10
9) A fi ller panel is included to accomodate multiple cabinet
depths. Inside the hood are (2) thumb screws located
on the left and right sides at the back of the hood,
Fig.10A. Turn each thumb screw clockwise to push
the fi ller panel towards the wall, Fig.10B. Tighten thumb
screws until fi ller panel meets the wall and is secured in
place. See hood specifi cations on page 8 for supported
cabinet depths.