![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/ca/fca34441-0a55-4ed1-bcb3-4d3e4efe8e9f/fca34441-0a55-4ed1-bcb3-4d3e4efe8e9f-bga3.png)
Appendix A Specifications|
A-2 Revision July 2008, EG03, SW V1.06
General Specifications
Other Functions
AVR, 2 types of S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records,
Reverse inhibition, DC Braking, Momentary Power Loss restart, Auto torque and slip
compensation, PID Control, Parameter Lock/Reset, Frequency Limits, Adjustable
Carrier Frequency
Protection
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating,
External Fault, Electronic thermal, Ground Fault, Phase-loss
Cooling Methods Forced Fan-cooled
Installation Location Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Pollution Degree 2
Ambient Temperature -10
o
C to 40
o
C Non-Condensing and not frozen
Storage/ Transportation
Temperature
-20
o
C to 60
o
C
Ambient Humidity Below 90% RH (non-condensing)
Environment
Vibration 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz